AC winding drives
|
Technical data
|
|
Winder Type
|
Size IEC
|
Torque
Md (Nm)
|
synchronous speed nS (min-1)
|
calculation speed nB (min-1)
|
power consumption winder (A) 3x400V; 50Hz
|
power consumption blower (A) 230V; 50Hz
|
|
Protection class IP 54
|
|
F 463
|
63
|
1,0
|
1500
|
1200
|
0,43
|
0,12
|
|
F 471
|
71
|
1,6
|
1500
|
1200
|
0,76
|
0,12
|
|
F 472
|
71
|
2,0
|
1500
|
1200
|
0,9
|
0,12
|
|
F 480
|
80
|
3,0
|
1500
|
1200
|
1,38
|
0,25
|
|
F 481
|
80
|
3,5
|
1500
|
1200
|
1,52
|
0,25
|
|
F 490
|
90 S
|
3,7
|
1500
|
1200
|
1,52
|
0,25
|
|
F 491
|
90 L
|
4,9
|
1500
|
1200
|
1,66
|
0,25
|
|
F 4100
|
100
|
5,0
|
1500
|
1200
|
2,2
|
0,25
|
|
F 4102
|
100
|
6,5
|
1500
|
1200
|
3,25
|
0,25
|
|
F 4112
|
112 S
|
6,8
|
1500
|
1200
|
2,85
|
0,27
|
|
F 4113
|
112 M
|
9,0
|
1500
|
1200
|
4,0
|
0,27
|
|
F 4114
|
112 ML
|
11,0
|
1500
|
1200
|
4,6
|
0,27
|
|
|
|
F 8100
|
100 L
|
8,0
|
750
|
600
|
2,0
|
0,25
|
|
F 8112
|
112 S
|
13,0
|
750
|
600
|
2,85
|
0,27
|
|
F 8113
|
112 M
|
15,0
|
750
|
600
|
3,6
|
0,27
|
|
|
|
S 490
|
90 L
|
1,0
|
1500
|
1200
|
0,38
|
self-ventilated
|
|
S 4112
|
112 S
|
1,6
|
1500
|
1200
|
0,8
|
|
|
|
S 871
|
71
|
1,0
|
750
|
600
|
0,33
|
self-cooling
|
|
S 880
|
80
|
1,6
|
750
|
600
|
0,43
|
|
S 890
|
90
|
2,0
|
750
|
600
|
0,52
|
|
S 8100
|
100
|
2,6
|
750
|
600
|
0,59
|
|
|
|
S 1280
|
80
|
1,1
|
500
|
400
|
0,24
|
self-cooling
|
|
S 1290
|
90
|
2,6
|
500
|
400
|
0,58
|
|
S 12100
|
100
|
3,5
|
500
|
400
|
0,67
|
|
S 12112
|
112
|
5,5
|
500
|
400
|
1,14
|
|
Protection class IP 21 S
|
|
K 4132
|
132 S
|
15,60
|
1500
|
1200
|
6,46
|
0,85
|
|
K 4133
|
132 M
|
28,50
|
1500
|
1200
|
11,4
|
0,85
|
|