Constant current controller for magnetic powder clutches / brakes
Magnetic powder clutches / brakes which are energized by the Controller M301 are showing no torque change resulting from heating
Construction of the device: Plug-in card / Eurocard 160x100 mm, with front panel for 19" rack, 3 U, 14 HP
|
|
mains potential free
|
|
|
output current max. 1A, output voltage max. 24 VDC
|
|
|
voltage supply 24 VDC or 24 VAC, 50-60 Hz
|
|
|
via isolation transformer 230 V/24 VAC 50-60 Hz, 63 VA (Option)
|
|
|
control inhibit
|
|
|
set-point voltage 0-10 VDC
|
|
|
set-point integrator ± adjustable
|
|
|
additional reference input 0-10 VDC
|
|
|
min. / max. current limit adjustable
|
|
|
Quick Stop Function
|
|
|
friction compensation adjustable
|
|
|
thermal protection via external sensor
|
|
|
potential free thermal relay contact (NC / NO contact)
|
|
|
display for RSP, thermal protection, ON/OFF, QUICK-STOP
|
Controller M2302
Constant current controller for magnetic powder clutches / brakes Magnetic powder clutches / brakes which are energized by the Controller M2302 are showing no torque change resulting from heating.
Fields of application: Unwind brakes / winding, torque controls, torque limitations, speed controls, clutch processes, start controls.
Programmable via option “Z2” for: tension control, brake power control, torque measurement, dancer control
Construction of the device: in a cartridge body IP20 with front panel for 19" rack, 3 U, 21 HP for wall mounting on DIN mounting rail in a wall housing type IP54
|
|
mains potential free
|
|
|
output current max. 2A
|
|
|
output voltage max. 42 VDC
|
|
|
voltage supply 230 VAC 50-60 Hz
|
|
|
control inhibit
|
|
|
set-point voltage 0-10 VDC
|
|
|
set-point integrator ± adjustable
|
|
|
additional reference input 0-10 VDC
|
|
|
min. / max. current limit adjustable
|
|
|
Quick Stop Function
|
|
|
friction compensation adjustable
|
|
|
thermal protection via external sensor
|
|
|
potential free thermal relay contact (NC / NO contact)
|
|
|
display for RSP, thermal protection, ON/OFF, QUICK-STOP
|
OPTIONS
|
|
operation panel, 3U / 14HP, with potentiometer / switch / indicator lamp
|
|
|
PID-Controller Z2 with ampere meter for tension / pressure / dancer control
|
|