Technical data
|
Tension measurement for profiles
|
|
bridge resistance
|
120...800 Ohm
|
|
bridge supply current
|
15mA or 1mA
|
|
temperature influence on bridge supply
|
< 0,005 % / K
|
|
sensitivity
|
1mV... 0,1V adjustable
|
|
corresponding amplification
|
500....10.000
|
|
low-pass filter 5.order limit frequency 5Hz selectable
|
|
input resistance
|
> 1 MOhm
|
|
zero drift(at V=1000)
|
< 1,8 mV/K
|
|
total drift(at V=1000)
|
< 2 mV/K
|
|
linearity error
|
< 0,1 %
|
|
measurement frequency range
|
0...5Hz with filter, 0...20Hz without filter
|
|
output for display instrument
|
1 mA measuring instrument
|
|
voltage output 0...10VDC
|
load resistance R > 1 kOhm
|
|
applied power output 0(4)...20mA
|
load resistance R < 500 Ohm
|
|
zero suppression
|
15 mV
|
|
mains connection
|
230 V, 50/60 Hz DV ±10% option: 24 VDC
|
|
input power
|
max. 4,5 VA
|
|
protection class
|
IP00
|
|
design
|
plug-in card 19“
|
|
connection via plug socket
|
32 poles a+c acc. to DIN 41612 type C
|